Home> Industry Information> Analysis of the Cause of No Drainage in Multistage Slurry Pump

Analysis of the Cause of No Drainage in Multistage Slurry Pump

July 27, 2023

We use the multi-stage Slurry Pump in the process, I am afraid that the most problems encountered is that the slurry pump no water. So when such a failure, how do we deal with it please go with Xiaobian take a look! Multi-level slurry pump causes no water (a) the water inlet pipe and the pump body: (1) Before the start of the pump is not filled with enough water, sometimes it seems that irrigation water has overflowed from the vents, but did not turn the pump shaft air completely discharged, resulting in a little air remaining in the inlet pipe or pump body. (2) The horizontal section of the inlet pipe in contact with the pump applies a descending gradient of 0.5% or more to the direction of the flow of water, and the one end connected to the inlet of the pump is the highest, not completely horizontal. If you tilt up, there will be trapped air inlet pipe, reducing the vacuum hose and pump, affecting water absorption. (3) The packing of the pump is worn or the packing pressure is too loose due to the long-term use, resulting in a large amount of water being ejected from the gap between the packing and the shaft sleeve of the pump. As a result, external air flows into the pump from these gaps, Affected the mention of water. (4) Inlet pipe Due to long-term potential underwater, pipe wall corrosion holes, water pumps continue to decline after work, when these holes exposed water, the air from the hole into the civilian into the water pipe. (5) cracks in the inlet pipe cracks, inlet pipe and pump connections appear tiny gaps, are likely to make the air into the inlet pipe. (B) pump speed is too low: (1) human factors. Some users due to the original motor damage, it is coupled with another motor driven, the result of a small flow, low lift or even the consequences of the water. (2) the pump itself mechanical failure. Loosening of the Impeller and the shaft of the pump shaft or the deformation and bending of the shaft of the pump cause the impeller to move more, friction directly with the pump body or damage to the bearing, all of which may reduce the speed of the pump. (3) power machine repair is not working. Motor due to the winding burned, and lost magnetism, the maintenance of the winding turns, diameter, wiring changes, or maintenance failure is not completely ruled out the factors that will change the pump speed. (C) suction is too large: some deep water, some water outside the flat topography, while ignoring the pump allowable suction, resulting in less water absorption or simply can not absorb the results of the water. To know the pump suction port can establish a degree of vacuum is limited, the absolute vacuum suction is about 10 meters high water column, and the pump can not establish an absolute vacuum. And the vacuum is too large, easy to pump the water gasification, the work of the pump negative. Therefore, the centrifugal pump has its maximum allowable suction, usually between 3-8.5 meters. Do not install the pump only easy and simple. (D) of the flow of water out of the resistance loss is too large: Some users after the measurement, although the reservoir or water tower to the water surface of the vertical distance is slightly less than the pump head, but still mention the amount of water or mention the water. The reason is often too long pipes, pipe corners, water flow resistance in the pipeline is too large loss. The reason is often too long pipes, pipe corners, water flow resistance in the pipeline is too large loss. Under normal circumstances, 90-degree elbow bend than the 120-degree bend resistance, each 90-degree elbow head loss of about 0.5-1 meters, 20 meters of pipe resistance can make head loss of about 1 meter. In addition, some users are also free to pump into and out of the pipe diameter, which also has a certain impact on the lift. (E) the impact of other factors: (1) at the end of the valve can not be opened. It is usually due to the pump being left on for too long, the bottom valve gasket is stuck, and the bottom valve without gasket may rust. (2) The bottom valve filter screen is clogged; or the bottom valve causes potential clogging of the filter screen in the sludge layer. (3) impeller wear serious. Impeller blades worn by long-term use, affecting the pump performance. (4) Gate valve can check valve failure or blockage will result in reduced flow or even pumping on the water. (5) Leakage of the outlet pipe will also affect the amount of water lift. (Editor: Huang Nengwen QQ:)

The above is the Analysis of the Cause of No Drainage in Multistage Slurry Pump we have listed for you. You can submit the following form to obtain more industry information we provide for you.

You can visit our website or contact us, and we will provide the latest consultation and solutions

Share to:

Send Inquiry

Home> Industry Information> Analysis of the Cause of No Drainage in Multistage Slurry Pump
Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send